specify type and interface for map
This commit is contained in:
		
							parent
							
								
									e515041d4e
								
							
						
					
					
						commit
						32b2237e19
					
				| @ -1,39 +1,48 @@ | ||||
| export { raidCalculations }; | ||||
| 
 | ||||
| const raidCalculations = { | ||||
| interface RaidType { | ||||
|   about: string, | ||||
|   requirements: string, | ||||
|   validate(num: number, size: number, stripeSize: number): boolean, | ||||
|   capacity(num: number, size: number, stripeSize: number, unit: number): number, | ||||
|   efficiency(num: number, stripeSize: number): number, | ||||
|   fault(num: number, size: number, unit: number): string, | ||||
| } | ||||
| 
 | ||||
| const raidCalculations: { [key: string]: RaidType } = { | ||||
|   raid_0: { | ||||
|     about: 'RAID 0 splits data evenly across 2 or more disks without redunancy or fault tolerance creating one large storage space. More info: <a href="https://en.wikipedia.org/wiki/Standard_RAID_levels#RAID_0" target="_blank">Wikipedia</a>', | ||||
|     requirements: 'RAID 0 requires at least 1 disk', | ||||
|     validate(num, size, stripeSize) { | ||||
|     validate(num: number, size: number, stripeSize: number) { | ||||
|       return num > 1; | ||||
|     }, | ||||
|     capacity(num, size, stripeSize, unit) { | ||||
|     capacity(num: number, size: number, stripeSize: number, unit: number) { | ||||
|       // total disks * size
 | ||||
|       return (num * size) * unit; | ||||
|     }, | ||||
|     efficiency(num, stripeSize) { | ||||
|     efficiency(num: number, stripeSize: number) { | ||||
|       // uses 100% of space
 | ||||
|       return 100; | ||||
|     }, | ||||
|     fault(num, size, unit) { | ||||
|     fault(num: number, size: number, unit: number) { | ||||
|       return 'None'; | ||||
|     }, | ||||
|   }, | ||||
|   raid_1: { | ||||
|     about: 'RAID 1 consists of an exact copy of the data (mirror) across two or more disks. The array will operate as long as at least one drive is operational.  More info: <a href="https://en.wikipedia.org/wiki/Standard_RAID_levels#RAID_1" target="_blank">Wikipedia</a>', | ||||
|     requirements: 'RAID 1 requires at least 1 disk', | ||||
|     validate(num, size, stripeSize) { | ||||
|     validate(num: number, size: number, stripeSize: number) { | ||||
|       return num > 1; | ||||
|     }, | ||||
|     capacity(num, size, stripeSize, unit) { | ||||
|     capacity(num: number, size: number, stripeSize: number, unit: number) { | ||||
|       // total size is size of a single drive
 | ||||
|       return size * unit; | ||||
|     }, | ||||
|     efficiency(num, stripeSize) { | ||||
|     efficiency(num: number, stripeSize: number) { | ||||
|       // 1/N
 | ||||
|       return (1 / num) * 100; | ||||
|     }, | ||||
|     fault(num, size, unit) { | ||||
|     fault(num: number, size: number, unit: number) { | ||||
|       // FT = total - 1
 | ||||
|       return `${num - 1} drive failures`; | ||||
|     }, | ||||
| @ -41,18 +50,18 @@ const raidCalculations = { | ||||
|   raid_5: { | ||||
|     about: 'RAID 5 uses block level striping with parity. This allows for fault tolerance with a storage reduction equal to one drive for the parity information. More info: <a href="https://en.wikipedia.org/wiki/Standard_RAID_levels#RAID_5" target="_blank">Wikipedia</a>', | ||||
|     requirements: 'RAID 5 requires at least 3 disks', | ||||
|     validate(num, size, stripeSize) { | ||||
|     validate(num: number, size: number, stripeSize: number) { | ||||
|       return num >= 3; | ||||
|     }, | ||||
|     capacity(num, size, stripeSize, unit) { | ||||
|     capacity(num: number, size: number, stripeSize: number, unit: number) { | ||||
|       // (N-1) * S (one drive for parity)
 | ||||
|       return ((num - 1) * size) * unit; | ||||
|     }, | ||||
|     efficiency(num, stripeSize) { | ||||
|     efficiency(num: number, stripeSize: number) { | ||||
|       // 1 - (1/N)
 | ||||
|       return (1 - (1 / num)) * 100; | ||||
|     }, | ||||
|     fault(num, size, unit) { | ||||
|     fault(num: number, size: number, unit: number) { | ||||
|       // always 1 failure
 | ||||
|       return '1 drive failure'; | ||||
|     }, | ||||
| @ -60,18 +69,18 @@ const raidCalculations = { | ||||
|   raid_6: { | ||||
|     about: 'RAID 6 is similiar to RAID 5 but with an additional parity block. This allows for an additional disk failure at the cost of storage reduction equal to two drives. More info: <a href="https://en.wikipedia.org/wiki/Standard_RAID_levels#RAID_6" target="_blank">Wikipedia</a>', | ||||
|     requirements: 'RAID 6 requires at least 4 disks', | ||||
|     validate(num, size, stripeSize) { | ||||
|     validate(num: number, size: number, stripeSize: number) { | ||||
|       return num >= 4; | ||||
|     }, | ||||
|     capacity(num, size, stripeSize, unit) { | ||||
|     capacity(num: number, size: number, stripeSize: number, unit: number) { | ||||
|       // (N-2) * S (2 parity)
 | ||||
|       return ((num - 2) * size) * unit; | ||||
|     }, | ||||
|     efficiency(num, stripeSize) { | ||||
|     efficiency(num: number, stripeSize: number) { | ||||
|       // 1 - (2/N)
 | ||||
|       return (1 - (2 / num)) * 100; | ||||
|     }, | ||||
|     fault(num, size, unit) { | ||||
|     fault(num: number, size: number, unit: number) { | ||||
|       // always 2 drive failures
 | ||||
|       return '2 drive failures'; | ||||
|     }, | ||||
| @ -79,18 +88,18 @@ const raidCalculations = { | ||||
|   raid_10: { | ||||
|     about: 'RAID 10 is a stripe of mirrors (RAID 1 + RAID 0). Each set of drives is mirrored and striped together so that each drive in the set is fault tolerant within the group. More info: <a href="https://en.wikipedia.org/wiki/Nested_RAID_levels#RAID_10_(RAID_1+0)" target="_blank">Wikipedia</a>', | ||||
|     requirements: 'RAID 10 requires an even number of at least 4 disks', | ||||
|     validate(num, size, stripeSize) { | ||||
|     validate(num: number, size: number, stripeSize: number) { | ||||
|       return num >= 4 && num % 2 === 0; | ||||
|     }, | ||||
|     capacity(num, size, stripeSize, unit) { | ||||
|     capacity(num: number, size: number, stripeSize: number, unit: number) { | ||||
|       // Total disks (stripe)/2 (mirror)
 | ||||
|       return ((num * size) / 2) * unit; | ||||
|     }, | ||||
|     efficiency(num, stripeSize) { | ||||
|     efficiency(num: number, stripeSize: number) { | ||||
|       // 1/2 (1/strips per stripe, 2 in this case)
 | ||||
|       return 50; | ||||
|     }, | ||||
|     fault(num, size, unit) { | ||||
|     fault(num: number, size: number, unit: number) { | ||||
|       // one per mirror
 | ||||
|       return '1 drive failure per mirrored set'; | ||||
|     }, | ||||
| @ -98,21 +107,21 @@ const raidCalculations = { | ||||
|   raid_50: { | ||||
|     about: 'RAID 50 stripes multiple RAID 5 arrays together (RAID 5 + RAID 0). Each RAID 5 set can sustain a single drive failure. More info: <a href="https://en.wikipedia.org/wiki/Nested_RAID_levels#RAID_50_(RAID_5+0)" target="_blank">Wikipedia</a>', | ||||
|     requirements: 'RAID 50 requires at least 6 disks with 3 minimum per stripe. Stripes must contain an equal number of disks.', | ||||
|     validate(num, size, stripeSize) { | ||||
|     validate(num: number, size: number, stripeSize: number) { | ||||
|       return num >= 6 && stripeSize >= 3 && num % stripeSize === 0; | ||||
|     }, | ||||
|     capacity(num, size, stripeSize, unit) { | ||||
|     capacity(num: number, size: number, stripeSize: number, unit: number) { | ||||
|       // RAID 5 per stripe
 | ||||
|       const perStripe = ((stripeSize - 1) * size) * unit; | ||||
| 
 | ||||
|       // sum each stripe
 | ||||
|       return perStripe * (num / stripeSize); | ||||
|     }, | ||||
|     efficiency(num, stripeSize) { | ||||
|     efficiency(num: number, stripeSize: number) { | ||||
|       // 1 - (1 / strips per stripe)
 | ||||
|       return (1 - (1 / stripeSize)) * 100; | ||||
|     }, | ||||
|     fault(num, size, unit) { | ||||
|     fault(num: number, size: number, unit: number) { | ||||
|       // one per set
 | ||||
|       return '1 drive failure per RAID 5 set'; | ||||
|     }, | ||||
| @ -120,21 +129,21 @@ const raidCalculations = { | ||||
|   raid_60: { | ||||
|     about: 'RAID 60 stripes multiple RAID 6 arrays together (RAID 6 + RAID 0). Each RAID 6 set can sustain a two drive failures. More info: <a href="https://en.wikipedia.org/wiki/Nested_RAID_levels#RAID_60_(RAID_6+0)" target="_blank">Wikipedia</a>', | ||||
|     requirements: 'RAID 50 requires at least 8 disks with 4 minimum per stripe. Stripes must contain an equal number of disks.', | ||||
|     validate(num, size, stripeSize) { | ||||
|     validate(num: number, size: number, stripeSize: number) { | ||||
|       return num >= 8 && stripeSize >= 4 && num % stripeSize === 0; | ||||
|     }, | ||||
|     capacity(num, size, stripeSize, unit) { | ||||
|     capacity(num: number, size: number, stripeSize: number, unit: number) { | ||||
|       // RAID 6 per stripe
 | ||||
|       const perStripe = ((stripeSize - 2) * size) * unit; | ||||
| 
 | ||||
|       // sum each stripe
 | ||||
|       return perStripe * (num / stripeSize); | ||||
|     }, | ||||
|     efficiency(num, stripeSize) { | ||||
|     efficiency(num: number, stripeSize: number) { | ||||
|       // 1 - (2 / strips per stripe)
 | ||||
|       return (1 - (2 / stripeSize)) * 100; | ||||
|     }, | ||||
|     fault(num, size, unit) { | ||||
|     fault(num: number, size: number, unit: number) { | ||||
|       // 2 per set
 | ||||
|       return '2 drive failures per RAID 6 set'; | ||||
|     }, | ||||
|  | ||||